BCA2000 NDIR/O2

DESCRIPTION
The BCA Models 2000 Series NDIR/O2 digital analyzer product line is designed around a state of the art 16 bit microprocessor, with 16 digital inputs, 5 digital outputs, 16 analog inputs and 5 analog outputs. The analyzer can be manually operated from the keypad or remotely via RS-232C communications and discrete inputs. The analyzer display includes screen presentation of all analyzer alarms. For precision measurements, the analyzer's accuracy is increased by entering calibration curve fit polynomials. Automatic calibration may be activated locally or remotely and includes auto cal via preset times.

METHOD OF OPERATION - NDIR
The BEICHENG Analytical Tech's NDIR analyzer is based on the infrared absorption characteristics of gases. Using a single infrared beam to measure gas concentrations, this analyzer produces highly stable and reliable results. A single infrared light beam is modulated by a chopper system and passed through a sample cell of predetermined length containing the gas sample to be analyzed. As the beam passes through the cell, the sample gas absorbs some of its energy. The attenuated beam (transmittance) emerges from the cell and is introduced to the front chamber of a two-chamber infrared microflow detector. The detector is filled with the gas component of interest and consequently the beam experiences further energy absorption. This absorption process increases the pressure in both of the chambers. The differential pressure between the front and rear chambers of the detector causes a slight gas flow between the two chambers. This flow is detected by a mass-flow sensor and is converted into an output signal.

METHOD OF OPERATION - OXYGEN
The BCA' oxygen analyzer section utilizes the electrochemistry method to determine the percent level of oxygen contained in the sample gas. The oxygen level is displayed on the LCD panel in engineering units.

FEATURES
   • Measures from 0-50 ppm up to 100% Full Scale (CO / CO2 / CH4 / THC / SO2)
   • Measures Oxygen (O2) from 0-30%
   • Multi-Component
   • Four User Definable Ranges per Component
   • Fast Response Time
   • Auto Ranging / Auto Calibration
   • Comprehensive Diagnostics
   • Output Options: Analog (User Scalable), (RS232)
   • Displays & Outputs: Concentrations, Diagnostics, Alarms & Preventative Maintenance
   • Remote Monitoring & Control

APPLICATIONS
   • Stack Gases (CEM)
   • Combustion Efficiency
   • Turbine/Generator Feedback Control
   • Process Chemical Gas Analysis
   • Personnel Safety
   • Fuel Cell Analysis
   • Vehicle Emissions

SPECIFICATIONS
IR ANALYSIS METHOD Non-Dispersive Infrared (NDIR)
NDIR COMPONENTS CO / CO2 / CH4 / THC / SO2 / O2
DETECTOR TYPE Microflow
RESPONSE TIME (IR) T90 < 10
IR SAMPLE CELL Stainless Steel with Replaceable Gold Cell Liner
RESOLUTION 0.0001 (Displays Five Significant Digits)
REPEATABILITY Better than 1.0% of Full Scale
LINEARITY Better than 0.5% of Full Scale of Factory Calibrated Ranges
NOISE Less than 1% of Full Scale of Factory Calibrated Ranges
ZERO & SPAN DRIFT Less than 1% of Full Scale per 24 Hours
ZERO & SPAN ADJUSTMENT Via front panel, TCP/IP or RS-232
SAMPLE FLOW RATE 0.25 to 2.0 LPM (Consult factory for other flow rates)
OXYGEN ANALYSIS METHOD Paramagnetic
O2 RANGES 0 - 1% up to 0-24% O2 Full Scale
O2 RESPONSE TIME T90 < 10 Seconds
600 SERIES FEATURES:
OUTPUTS AVAILABLE TCP/IP, RS232, Four Scalable Analog 0-10 V / 4-20 mA
(Allows Offset & Expandable Range DC Analog Outputs)
DISCRETE CONTROL
Remote/Local Control, Range Change, Range Sense
Mode (All TTL Logic)
DISCRETE ALARMS
(Local & Remote Adjustable) General Fault/ TTL Logic (Ground True)
Calibration Failure/ TTL Logic (Ground True)
Concentration (2 each)/ TTL Logic (Ground True)
DIGITAL DIAGNOSTICS Pressure
Temperatures Pressure Control Voltages
Flow Parameters
KEYPAD DISPLAYS Factory Settings
Full Scale Range Select
Auto Cal Times
SPECIAL FEATURES Auto Ranging
Auto Calibration (adjustable through internal clock)
DISPLAY 3" x 5" Back lit LCD
SAMPLE TEMPERATURE Up to 50°C, Non-condensing
AMBIENT TEMPERATURE 5 to 45°C
AMBIENT HUMIDITY Less than 90% RH Non-condensing
WARM-UP TIME 20 Minutes
POWER REQUIREMENTS 115/230 (±10%) VAC; 50/60 Hz;
DIMENSIONS 180×483×350 (mm)
WEIGHT 20kg
Specifications are subject to change without notice.

[Home][Products][Applications][News][Sales][Manufactory][Intercourse][People][中 文]

© Copyright BC Analytical Inc. All rights reserved

chanel watches chanel replica watches replica chanel watches chanel watch chanel handbags chanel replica handbags replica chanel handbags chanel watches chanel watch chanel replica watch gucci watches gucci replica watches gucci watch louis vuitton handbags louis vuitton bags chanel j12 watches chanel watches chanel replica watches louis vuitton replica watches louis vuitton watches louis vuitton chanel 2.55 ghd straighteners ghd hair straightener ghd vibram five fingers vibram five fingers shoes chanel watches chanel replica watches chanel watch MBT Shoes discount mbt shoes cheap mbt shoes mbt shoes clearance